The Mock Urban Settings Test (MUST) took place at the Dugway Proving Grounds (DPG) in Utah from Sept. 10-27, 2001 (Biltoft, 2001). This building array transport and dispersion experiment included a large number of continuous and puff releases and a high density of concentration and wind measurements (Biltoft et al, 2002). The MUST experiment, sponsored by the Defense Threat Reduction Agency and coordinated by the US Army DPG, was a multi-national collaborative effort. In this paper, preliminary analyses from one night of measurements of the wind and turbulence fields upstream and within the first canyon of a building array are presented.
机译:模拟城市环境测试(MUST)于2001年9月10日至27日在犹他州的Dugway试验场(DPG)进行(Biltoft,2001年)。该建筑物阵列的运输和分散实验包括大量连续释放和粉扑释放,以及高浓度的浓度和风的测量(Biltoft等,2002)。由国防部减少威胁局赞助并由美国陆军DPG协调的MUST实验是一项跨国合作。本文介绍了从一晚对建筑物阵列的第一个峡谷内和上游的风场和湍流场进行测量的初步分析。