This paper deals with the performance monitoring and modelling of a capacity-controlled high-temperature air-to-water heat pump with injection cycle installed in a low-insulated house in Belgium. It is used for space heating and domestic hot water production. The monitoring consists of measuring in detail the performance of the system. The interest is in the fact that the heating system has been changed twice since the beginning of the monitoring so that we have results with radiators, convector heaters and a heating floor.rnBesides, a model of the heat pump and each heating system has been developed in the TRNSYS environment. The heat pump is defined statically by a table with manufacturer data values while dynamic thermal models of the house and of the heating system are used.rnFirstly, we present the monitoring results of the heat pump in space heating mode and in domestic hot water production mode. Secondly, we present the results of the model with each of the three heating systems. Finally, we compare the measurements with the results coming from the model.
机译:本文针对安装在比利时一间低绝缘房屋中,具有注入循环的容量控制的高温空气对水热泵的性能监控和建模进行了研究。它用于空间供暖和生活热水生产。监视包括详细测量系统性能。有趣的是,自监测开始以来,加热系统已进行了两次更换,因此我们得到了散热器,对流加热器和加热地板的结果。rn此外,还开发了热泵和每个加热系统的模型在TRNSYS环境中。通过使用制造商数据值的表格来静态定义热泵,同时使用房屋和供暖系统的动态热模型。rn首先,我们介绍空间供热模式和生活热水生产模式下热泵的监控结果。 。其次,我们介绍了三个加热系统中每一个的模型结果。最后,我们将测量结果与模型结果进行比较。