Partial Discharge Inception Voltage of Enameled Cellular Wire under Impulse Voltage

机译:脉冲电压下漆包线的局部放电起始电压

获取原文
获取原文并翻译 | 示例

摘要

In order to suppress partial discharge (PD) generated in the wedge gap between an inverter drive motor windings due to overvoltage, the authors have developed a low permittivity film with micro cellular in an insulating layer resin. An attempt is made to measure partial discharge inception voltage (PDIV) for twisted pair sample of insulating film with micro cellular in the resin. This paper deals with experimental and analytical investigation on improved PDIV owing to micro cavities in the insulating layer under AC and impulse voltage application. Measured PDIV under AC and impulse voltage application is interpreted quantitatively in terms of Volume-Time theory which considers the generation probability of initial electrons supplied from both the solid insulating material surface and the wedge gap volume as well as a streamer inception criterion.
机译:为了抑制由于过电压而在逆变器驱动电动机绕组之间的楔形间隙中产生的局部放电(PD),作者开发了一种在绝缘层树脂中具有微孔的低介电常数膜。尝试测量在树脂中具有微孔的绝缘膜双绞线样品的局部放电起始电压(PDIV)。本文针对由于交流电和脉冲电压作用下绝缘层中的微腔而产生的改进的PDIV进行了实验和分析研究。根据体积-时间理论定量解释了在交流电和脉冲电压作用下测得的PDIV,该理论考虑了从固体绝缘材料表面和楔形间隙体积提供的初始电子的产生概率,以及流注起始准则。