This paper proposes a probabilistic method aimed at estimating the voltage sag frequency of non-monitored sites given the number of sags recorded by a limited set of voltage sag monitors. The proposed method is based on simulating a representative database of feasible pseudo-measurements by using probabilistic values of fault coefficient, fault impedance, fault type, and fault location. This information is processed through Bayesian filtering based on the Bayes' probabilistic theorem. This allows obtaining the most probable voltage sag index at non-monitored busbars given the index measured at monitored busbars. This statistical estimation of sag indices at locations where there are no monitors constitutes the main contribution of this work. This study is developed in three power systems, the IEEE 24-busbar reliability test system, the IEEE 18-busbar test system and the transmission network of Ecuador with 357 busbars.
机译:本文提出了一种概率方法,旨在根据给定的有限电压骤降监视器集记录的下垂次数来估计非监视站点的电压下垂频率。所提出的方法是基于使用故障系数,故障阻抗,故障类型和故障位置的概率值模拟一个可行的伪测量的代表性数据库。该信息通过基于贝叶斯概率定理的贝叶斯滤波处理。给定在受监视母线上测量的指数,这可以在非受监视母线上获得最可能的电压骤降指数。在没有监测器的地方,这种下垂指数的统计估计是这项工作的主要贡献。这项研究是在三个电源系统中进行的:IEEE 24母线可靠性测试系统,IEEE 18母线测试系统以及厄瓜多尔的357母线传输网络。