Commutation failure is a kind of common failure type for Ultra High Voltage Direct Current (UHVDC) system, and its influence on hybrid AC/DC system are widely studied by researchers. Based on the detailed hybrid AC/DC system model, established in electromagnetic transient simulation software PSCAD/EMTDC, dynamic characteristics of the hybrid system under commutation failure, and key influence factors for commutation failure degree, are researched in this paper. In the model, UHVDC is connected to the AC system through double circuit transmission lines. Research results show that, the established hybrid AC/DC system model in this paper can reflect electromagnetic properties of different operation conditions, especially for commutation failure condition, and strength of AC system, fault type, fault resistance and other factors will have an apparent impact on commutation failure degree, laying solid foundations for subsequent protection related issues in hybrid AC/DC system.
机译:换相故障是超高压直流(UHVDC)系统的一种常见故障类型,研究人员广泛研究了它对混合AC / DC系统的影响。本文基于电磁暂态仿真软件PSCAD / EMTDC中建立的详细的混合AC / DC系统模型,研究了混合系统在换相失败时的动态特性以及对换相失败程度的关键影响因素。在该模型中,UHVDC通过双回线传输线连接到AC系统。研究结果表明,所建立的交流/直流混合系统模型可以反映不同工况下的电磁特性,特别是对于换相失败工况,对交流系统的强度,故障类型,故障电阻等因素有明显的影响。换相失败程度的研究,为交流/直流混合系统后续保护相关问题奠定了坚实的基础。