首页> 外文会议>2017 23rd IEEE International Conference on Automation andomputing >Dynamic modelling and simulation of a combined-cycle power plant integration with thermal energy storage
【24h】

Dynamic modelling and simulation of a combined-cycle power plant integration with thermal energy storage

机译:具有热能存储的联合循环电厂集成的动态建模和仿真

获取原文
获取原文并翻译 | 示例

摘要

The Combined-Cycle Gas Turbine (CCGT) power plants are increasingly required to provide the service for balancing the load demand and power supply with the increase of the intermittent power generation from renewable energy sources. To ensure CCGT power plants to operate flexibly and efficiently, it is necessary to find the suitable strategy. This paper presents the feasibility of a CCGT power plant combined with the Thermal Energy Storage (TES) to improve the plant operation flexibility. The dynamic simulation models of a 420MW CCGT power plant and TES system are presented in this paper. The TES charging and discharging strategies are investigated. The simulation results show that TES charging or discharging processes provide the additional mechanisms for regulating the output power of the CCGT power plant.
机译:越来越多的联合循环燃气轮机(CCGT)发电厂需要提供服务,以平衡负载需求和电力供应,同时还要增加可再生能源的间歇性发电量。为了确保CCGT电厂灵活高效地运行,有必要找到合适的策略。本文介绍了将CCGT电厂与热能存储(TES)结合使用以提高电厂运行灵活性的可行性。提出了420MW CCGT电厂和TES系统的动态仿真模型。研究了TES的充放电策略。仿真结果表明,TES的充电或放电过程为调节CCGT电厂的输出功率提供了额外的机制。