This paper analyzes the reciprocity, symmetry and port decoupling effect in real home PLC networks. The reciprocity has an impact on the fact that the input and output ports of a PLC link are decoupled, and the study on the symmetry can explain the reason for the decoupling effect. The analysis of experimental data in the band 2???100 MHz shows that the PLC channel is reciprocal and that the input-output ports are largely decoupled. In turn, the port decoupling property implies that impedance matching at the transmitter and receiver ports can be implemented independently one from the other. That is, the choice of the receiver impedance does not have effect on the choice of the transmitter impedance and vice versa, in home broad band PLC systems.
机译:本文分析了实际家庭PLC网络中的互易性,对称性和端口解耦效应。互易性影响PLC链接的输入和输出端口解耦的事实,而对对称性的研究可以解释这种解耦效应的原因。对2×100 MHz频带内的实验数据的分析表明,PLC通道是互易的,并且输入/输出端口在很大程度上是去耦的。进而,端口去耦特性意味着可以在发射器和接收器端口上彼此独立地实现阻抗匹配。即,在家用宽带PLC系统中,接收器阻抗的选择对发送器阻抗的选择没有影响,反之亦然。