【24h】

Reliability study on smart electricity meter

机译:智能电表的可靠性研究

获取原文
获取原文并翻译 | 示例

摘要

In order to evaluate the performance of smart electricity meter (SEM), this paper studies the reliability of the SEM. We introduce the indication of the reliability and analyze the standards and documents relevant to SEM. Then, we use the component stress method to predict the reliability of SEM based on the study of SEM. Finally, through an example, we obtain the expected failure rate of SEM from the kind of DDZY102C-Z produced by the Wasion Group through the method proposed. The result of the predicted reliability of the SEM is 5640.43 FIT (failure in time: 10-9Failures/h). Furthermore, in order to validate the proposed method, accelerated test is taken to assess the reliability of the smart electricity meter, and the experimental results show that the predicted reliability of the SEM has a high credibility.
机译:为了评估智能电表(SEM)的性能,本文研究了SEM的可靠性。我们介绍可靠性的指标,并分析与SEM相关的标准和文件。然后,在研究SEM的基础上,采用分应力法对SEM的可靠性进行了预测。最后,通过一个实例,通过提出的方法,从Wasion Group生产的DDZY102C-Z中获得了SEM的预期故障率。 SEM的预测可靠性结果为5640.43 FIT(时间失败:10-9Failures / h)。此外,为验证该方法的有效性,通过加速试验对智能电表的可靠性进行了评估,实验结果表明,所预测的SEM可靠性具有较高的可信度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有