It is well known that preventive tests have been widely used as an important means to ensure reliable operation of the power cable. Nevertheless, in the early stages of insulation deterioration, the traditional preventive tests cannot effectively detect the faint abnormal signals caused by defects. As insulation failure usually starts with PD activities, which is not only one of the primary reasons to cause the insulation deterioration of the cable, but also the characteristic scalar to describe the insulation state of cable. Therefore, PD diagnosis is recommended by IEC, IEEE and CIGRE as an effective method to evaluate the properties of cable insulation condition. In order to study the PD characteristics of the typical defects in XLPE(Cross-Linked Polyethylene)power cable, two PD models as protrusion defect of cable joint and void defect in main insulation were designed, and then the PD measurement and analysis system based on the PDBase was established. The PD characteristics of typical defects were detected and compared, also the effects of the applied voltage on the phase-resolved PD (PRPD) pattern, waveform characteristic, discharge frequency, center-phase distribution and statistical features were investigated. The experimental results indicated that it has the high stability and repeatability of the discharge on the identical defect model under the same condition. The discharge development process, PRPD patterns, time domain waveforms, central phase changing of PD signals and statistical features had very similar distribution characteristics and those of different defect had different ones. So it provides a test basis for the pattern recognition of PD types and a deeper study on the PD mechanism of XPLE cable.
机译:众所周知,预防性测试已广泛用作确保电力电缆可靠运行的重要手段。然而,在绝缘劣化的早期阶段,传统的预防性测试不能有效地检测出由缺陷引起的微弱的异常信号。由于绝缘故障通常始于PD活动,这不仅是导致电缆绝缘性能下降的主要原因之一,而且还是描述电缆绝缘状态的特征标量。因此,IEC,IEEE和CIGRE推荐使用PD诊断作为评估电缆绝缘条件特性的有效方法。为了研究交联聚乙烯电缆典型缺陷的局部放电特性,设计了两种局部放电模型,分别是电缆接头突出缺陷和主绝缘中的空缺缺陷,然后基于此模型进行了局部放电测量分析系统。 PDBase已建立。检测并比较了典型缺陷的局部放电特征,并研究了施加电压对相分辨局部放电(PRPD)图案,波形特征,放电频率,中心相位分布和统计特征的影响。实验结果表明,在相同条件下,在相同缺陷模型下,放电具有很高的稳定性和重复性。放电的发展过程,PRPD图,时域波形,PD信号的中心相变和统计特征具有非常相似的分布特征,而不同缺陷的特征具有不同的分布特征。因此,它为PD类型的模式识别提供了测试依据,并为XPLE电缆的PD机制的深入研究提供了依据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号