This paper presents a review of power-system synchronization, proper sync-check coordination, and fast synchronization methods. When paralleling two sources, it is crucial that the interconnecting circuit breaker be closed only when both sources are in voltage, frequency, and phase coincidence. An operator can synchronize manually or use one of the latest, state-of-the-art automatic synchronizers (ANSI/IEEE device 25A) [1] and sync-check relays (ANSI/IEEE device 25) to automate closing. Generator and bus synchronization share most principles-with some important differences-for each type of synchronization. For generation plants, the method of generator synchronization selected depends greatly on the plant configuration and operating mode. For bus-line applications, the synchronizing method selected depends on the power-system "stiffness", motor loads, and whether a wye-delta transformer is located between the line and bus.
机译:本文介绍了电源系统同步,适当的同步检查协调和快速同步方法。当并联两个电源时,至关重要的是,只有当两个电源的电压,频率和相位一致时,才应闭合互连断路器。操作员可以手动同步,也可以使用最新的最新自动同步器(ANSI / IEEE设备25A)[1]和同步检查继电器(ANSI / IEEE设备25)来自动关闭。对于每种类型的同步,生成器和总线同步共享大多数原理(但有一些重要区别)。对于发电厂,发电机同步的选择方法很大程度上取决于发电厂的配置和运行模式。对于总线线路应用,选择的同步方法取决于电源系统的“刚度”,电动机负载以及线路和总线之间是否安装了星形-三角形变压器。