摘要

Circuit breaker failure protection (CBFP) is a widely used back-up protection in electrical power system. To avoid maloperation, the CBFP needs a long delay to confirm the status of the circuit breaker, which means the cut off time will be long, sometimes too long to keep the stability of the power system. Therefore, it is very important to propose an optimized method to calculate the CBFP delay time for improving the stability of the system. A CT current tail truncation algorithm based on a CT tailing current-short circuit current criterion plane has been shown in this paper, which can truncate CT tailing current quickly and thereby shorten the delay of CBFP. Without special configuration of P level CT, this algorithm ensures the reliability and rapidity of CBFP, significantly reduces the risk of system operation, and has good economic benefits.
机译:断路器故障保护(CBFP)是电力系统中广泛使用的备用保护。为避免误操作,CBFP需要较长的时间来确认断路器的状态,这意味着切断时间会很长,有时甚至会太长,无法保持电源系统的稳定性。因此,提出一种优化方法来计算CBFP延迟时间对于提高系统的稳定性非常重要。提出了一种基于CT尾电流-短路电流准则平面的CT电流尾截断算法,该算法可以快速截断CT尾电流,从而缩短了CBFP的延迟。该算法无需特殊配置的P级CT,可以保证CBFP的可靠性和快速性,大大降低了系统运行的风险,具有良好的经济效益。