首页> 外文会议>2016 IEEE 6th International Conference on Power Systems >Time-variant slope compensation for peak current mode control (PCMC) of boost converter with point-of-load applications
【24h】

Time-variant slope compensation for peak current mode control (PCMC) of boost converter with point-of-load applications

机译:具有负载点应用的升压转换器的峰值电流模式控制(PCMC)的时变斜率补偿

获取原文
获取原文并翻译 | 示例

摘要

This paper describes the operation of a time-variant slope compensated peak current mode control (PCMC) for boost converter with POL configuration. The limitations of PCMC are minimized by introducing time-variant slope compensation and the effect of the RHP zero of boost converter is minimized by a type II compensator. The proposed work is evaluated and illustrated with wide range of line and load changes. Experimental results are presented for input range of 25V- 60V and load change of 0.6A - 2A with 400W power output at 10 kHz switching frequency. The transient response obtained is 25ms (250 cycles) for output voltage and the corresponding switch current stabilizes in 10ms (100 cycles) for 100% load changes respectively.
机译:本文介绍了具有POL配置的升压转换器的时变斜率补偿峰值电流模式控制(PCMC)的操作。通过引入时变斜率补偿,可将PCMC的局限性降至最低,并且通过II型补偿器可将升压转换器的RHP零级影响降至最低。对拟议的工作进行了评估,并说明了各种线路和负载变化。给出了在25V至60V的输入范围和0.6A至2A的负载变化以及在10 kHz开关频率下具有400W功率输出的实验结果。对于输出电压,获得的瞬态响应为25ms(250个周期),对于100%的负载变化,相应的开关电流分别稳定在10ms(100个周期)内。