首页> 外文会议>2016 17th International Conference on Harmonics and Quality of Power >ICA-based method for power quality disturbance detection
【24h】

ICA-based method for power quality disturbance detection

机译:基于ICA的电能质量扰动检测方法

获取原文
获取原文并翻译 | 示例

摘要

This paper presents a method based on Independent Component Analysis (ICA) for power quality disturbance detection. The proposed method focuses on the detection of sag, swell, sinusoidal voltage fluctuation, fundamental frequency variations and harmonics in electric power signals. Suitable results were achieved from simulated signals in which the beginning and ending time of these disturbances were accurately detected. The results showed the proposed method can be used for disturbance segmentation as part of a power quality monitoring system.
机译:本文提出了一种基于独立分量分析(ICA)的电能质量扰动检测方法。所提出的方法着重于检测电力信号中的下垂,膨胀,正弦电压波动,基频变化和谐波。从模拟信号中获得了合适的结果,在这些信号中,可以准确地检测到这些干扰的开始和结束时间。结果表明,该方法可作为电能质量监测系统的一部分用于扰动分割。