首页> 外文会议>2015 IEEE Eindhoven PowerTech >Investigation of suitability of cascading outage assessment methods for real-time assessment
【24h】

Investigation of suitability of cascading outage assessment methods for real-time assessment

机译:级联中断评估方法对实时评估的适用性调查

获取原文
获取原文并翻译 | 示例

摘要

This paper investigates the suitability of assessment methods for cascading outages for real-time assessment. A total of ten assessment methods for cascading outages are investigated, and for all of the investigated methods a complexity assessment is performed to assess the suitability of the method to real-time assessment. The investigation revealed that two of the methods are of special interest for further study on real-time assessment of cascading outages. These are the betweenness centrality model, based on network topology, and the manchester model, based on AC power flow.