A novel Virtual Measurement System (VMS) of ARINC429 bus signal electrical parameter is designed to improve test accuracy and maintenance efficiency of avionics devices. This software of the VMS is implemented based on Labwindows/CVI. The hardware of the VMS is constructed by using data acquisition card to test voltage parameters and by using microcontroller and voltage comparators to test time parameters. A communication radio panel is used to check ARINC 429 bus signal electrical parameters by using the VMS and the oscilloscope Rigol DS5102M. The Mean Square Error (MSE) of voltage parameters measured by the VMS is 0.002V, and that measured by the oscilloscope is 0.155V. And the MSE of time parameters measured by the VMS is 0.06tμs, and that measured by the oscilloscope is 0.09μs. The results show that the VMS has higher test accuracy in voltage and time parameter measurement than those of the oscilloscope.
机译:设计了一种新型的ARINC429总线信号电参数虚拟测量系统(VMS),以提高航空电子设备的测试精度和维护效率。 VMS的该软件基于Labwindows / CVI实现。 VMS的硬件是通过使用数据采集卡测试电压参数以及使用微控制器和电压比较器测试时间参数来构造的。通信无线电面板用于通过使用VMS和示波器Rigol DS5102M检查ARINC 429总线信号的电气参数。 VMS测量的电压参数的均方误差(MSE)为0.002V,示波器测量的均方误差为0.155V。 VMS测得的时间参数MSE为0.06tμs,示波器测得的时间参数MSE为0.09μs。结果表明,VMS在电压和时间参数测量方面具有比示波器更高的测试精度。