In this paper, a statistical approach for evaluating the transformer's paper insulation is proposed. The proposed approach adopts multi-variable analysis to investigate the correlations between the degree of polymerization (DP) of paper insulation and increase rates of different dissolved gases in oil. Moisture in paper, oxygen and temperature are important factors influencing paper insulation degradation and included in the investigation. The reliabilities of utilizing different dissolved gases in the evaluation of DP value of an oil-pressboard insulation system are examined. The significance test of dissolved gases is also performed to find the most influential gases in the estimation of DP value. Moreover, the mutual correlation between different dissolved gases is taken into account to improve the reliability of DP estimation. Extensive accelerated ageing experiments on model oil-pressboard insulation systems are conducted and the measurement results are used to validate the proposed approach.
机译:本文提出了一种评估变压器纸绝缘的统计方法。所提出的方法采用多变量分析来研究纸绝缘的聚合度(DP)与油中不同溶解气体的增加速率之间的相关性。纸张中的水分,氧气和温度是影响纸张绝缘性能下降的重要因素,已纳入调查范围。检查了在评估油压绝缘系统的DP值时利用不同溶解气体的可靠性。还进行了溶解气体的显着性测试,以在DP值的估算中找到最具影响力的气体。此外,考虑了不同溶解气体之间的相互关系,以提高DP估计的可靠性。在模型油压绝缘板系统上进行了广泛的加速老化实验,并将测量结果用于验证所提出的方法。