The article presents the results of an experiment designed to determine the impact of initial phases of higher harmonics of the supply voltage of a single-phase transformer on the power losses in its core. It has been shown that a reliable research of the impact of harmonic of the supply voltage of a transformer on its losses is possible, taking into account not only the amplitudes of these harmonics, but also their initial phases. This is particularly important in the context of often hastily formulated conclusions that the power losses in a transformer increase at its supply with a non-sinusoidal voltage. It has been also noted that low order harmonics have a major impact on the power losses in transformer core.
机译:本文介绍了旨在确定单相变压器电源电压高次谐波的初始相位对其铁心功率损耗的影响的实验结果。已经表明,不仅考虑这些谐波的幅度,而且考虑其初始相位,对变压器的电源电压的谐波对其损耗的影响进行可靠的研究是可能的。在经常草率得出结论的情况下,这一点尤其重要,因为得出结论:变压器的功率损耗在非正弦电压下会增加。还已经注意到,低阶谐波对变压器铁芯的功率损耗有重大影响。