首页> 外文会议>2014 International Conference on Power System Technology: Towards Green, Efficient and Smart Power System >Active islanding detection method based on grid-connected photovoltaic inverter and negative sequence current injection
【24h】

Active islanding detection method based on grid-connected photovoltaic inverter and negative sequence current injection

机译:基于并网光伏逆变器和负序电流注入的主动孤岛检测方法

获取原文
获取原文并翻译 | 示例

摘要

The photovoltaic power source would keep supplying power under unscheduled islanding operation, and hence bring potential risk for maintenance personnel and user equipments, so it is of great significance to enforce accurate and rapid islanding detection method. A method based on negative sequence current injection and voltage imbalance at the point of common coupling is proposed. The reasonable switching strategy of negative sequence current in the grid-connected inverter reduces the impact of injected current on the main power grid. The method, without non-detection zone, is also unaffected by asymmetric faults of the power grid. Case study shows that the method could detect islanding state accurately and quickly under the worst condition while the power of the PV matches the load power, and the voltage and the frequency of the PCC has small shift.
机译:光伏电源将在计划外的孤岛操作下持续供电,从而给维护人员和用户设备带来潜在的风险,因此,实施准确,快速的孤岛检测方法具有重要意义。提出了一种基于负序电流注入和公共耦合点电压不平衡的方法。并网逆变器中负序电流的合理切换策略可减少注入电流对主电网的影响。没有检测区域的方法也不受电网非对称故障的影响。实例研究表明,该方法能够在最差条件下准确,快速地检测出孤岛状态,而光伏发电的功率与负载功率相匹配,并且PCC的电压和频率漂移很小。