Clamp Rogowski coil current transformer (CT) with strong anti-interference ability, high installation flexibility and operational safety, are now being widely used to detect the partial discharge (PD) of the XLPE (cross-linked polyethylene) cables, especially in the situation where the cables are in operation and therefore needed to be on-line monitored in practical applications. Since Clamp Rogowski coil CT can be easily mounted on the cables without changing the structure of the cable accessories, a large degree of flexibility and convenience can be expected when they are used in electrical industries. Compared with uncut Rogowski coil CT, the windings of Clamp Rogowski coil CT are concentrated in half side and thus introduce air gap on the grounds that the core has to be cut into two parts. In this paper, the amplitude-frequency characteristics of Clamp Rogowski coil CT and uncut Rogowski coil CT were measured and analyzed in detail. During the measurement, a sine wave current with constant amplitude was input from the primary side of the coil, and the voltage amplitudes output from the secondary side of the coil were recorded by changing the frequency of the current. The experimental data were summarized and drawn into amplitude-frequency curves using Matlab software package. The comparative analysis of the experimental results showed that, within the frequency band of XLPE cable PD detection (500kHz∼10MHz), the difference in the output amplitudes of uniformly-winding and unevenly-winding Rogowski coil CT is less than 3.2%, while the difference between those of Rogowski coil CT and uncut Rogowski coil CT is less than 6%. It also shows that the influences of uneven winding and air gas on the amplitude-frequency characteristics of the transformer is very small after clamp Rogowski coil sensors have been used. The findings of this work may trigger some useful conceptions in the design of modern electronic transformer.
机译:具有强大的抗干扰能力,高安装灵活性和操作安全性的Clamp Rogowski线圈电流互感器(CT)现在被广泛用于检测XLPE(交联聚乙烯)电缆的局部放电(PD)。电缆在运行中的位置,因此在实际应用中需要进行在线监视。由于Clamp Rogowski线圈CT可以轻松安装在电缆上,而无需更改电缆附件的结构,因此在电气行业中使用它们时,可以期待很大的灵活性和便利性。与未切割的Rogowski线圈CT相比,Clamp Rogowski线圈CT的绕组集中在一半侧,因此由于必须将铁心切成两部分而引入了气隙。本文对Clamp Rogowski线圈CT和未切割Rogowski线圈CT的幅频特性进行了详细的测量和分析。在测量期间,从线圈的初级侧输入具有恒定幅度的正弦波电流,并且通过改变电流的频率来记录从线圈的次级侧输出的电压幅度。总结了实验数据,并使用Matlab软件包绘制了幅频曲线。实验结果的对比分析表明,在XLPE电缆PD检测频带(500kHz〜10MHz)内,均匀绕制和不均匀绕制的Rogowski线圈CT的输出幅度差异小于3.2%,而Rogowski线圈CT和未切割的Rogowski线圈CT的差值小于6%。这也表明,使用钳位式Rogowski线圈传感器后,绕组不均匀和空气气体对变压器的幅频特性的影响很小。这项工作的发现可能会触发现代电子变压器设计中的一些有用概念。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号