Based on the differences between UHVDC system and HVDC system, this paper introduces the new safety requirements of UHVDC earth electrode, elaborates the design process of UHVDC earth electrode and emphatically analyzes two design requirements: the maximum allowable step potential and the maximum allowable temperature. Analysis indicates that step potential in previous HVDC earth electrode design is quite strict and not suitable for the situation, the new standard is proposed. In addition, the body size of UHVDC earth electrode is unlike the previous HVDC earth electrode mainly limited by thermal stability, but is decided by step potential limits.
机译:基于特高压直流输电系统与高压直流输电系统的不同之处,介绍了特高压直流输电接地电极的新安全要求,阐述了特高压直流接地电极的设计过程,着重分析了两个设计要求:最大允许阶跃电位和最大允许温度。分析表明,以前的HVDC接地电极设计中的步进电位非常严格,不适合这种情况,因此提出了新的标准。另外,UHVDC接地电极的主体尺寸不同于以前的HVDC接地电极,主要受热稳定性限制,但由阶跃电位极限决定。