首页> 外文会议>2014 Intemational Conference of Lighbling Protection >Comparison of impulsive process superimposed on continuous current of triggered lightning
【24h】

Comparison of impulsive process superimposed on continuous current of triggered lightning

机译:触发雷电连续电流上叠加脉冲过程的比较

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Current data in triggered lightning has been analyzed for comparison on current peak, Rise time, Half-peak width and charge transfer of M-component and ICC pulse, they have quite similar GM values. Electric field for ICC pulse have been calculated with physical model, which has quite a good consistency with measured electric field in rising edge but a little inconsistent in falling edge, the result is nearly the same as result for M-component given by former research. By analysis, we consider M-component with peak value of some kilo-ampere associated with breakdown from partway of lightning channel, classical M-component and ICC pulse associated with streamer from charge source in cloud. Based on facts above, we consider M-component and ICC pulse probably rely on similar mechanism.
机译:分析了触发雷电中的电流数据以比较电流峰值,上升时间,半峰宽以及M分量和ICC脉冲的电荷转移,它们具有非常相似的GM值。用物理模型计算了ICC脉冲的电场,该电场与上升沿的实测电场具有很好的一致性,而在下降沿则有一些不一致,其结果与以前研究的M分量的结果几乎相同。通过分析,我们认为M分量的峰值与雷电通道中途的击穿相关联,峰值为几千安培,经典M分量以及与云中电荷源的流光相关的ICC脉冲。基于以上事实,我们认为M分量和ICC脉冲可能依赖于类似的机制。