首页> 外文会议>2014 IEEE Petroleum and Chemical Industry Technical Conference >Preventing centrifuge failures due to voltage distortion on a Drilling Rig
【24h】

Preventing centrifuge failures due to voltage distortion on a Drilling Rig

机译:防止由于钻机上的电压失真而导致离心机故障

获取原文
获取原文并翻译 | 示例

摘要

AC and DC Drives commonly used on land and offshore Drilling Rigs produce extremely high levels of harmonic distortion. With voltage distortion often exceeding 20%, equipment associated with the drilling operation can experience erratic operation and equipment damage. Repeated damage to one or several AC Drives is common. One land Rig in Northern Alberta was experiencing failures with its centrifuge equipment on a weekly basis. During one visit to the site, a Drive in the centrifuge was found to have tripped off causing the centrifuge to plug up. After cleaning out the centrifuge and restoring the Drive, it tripped off again shortly after drilling operations resumed. A Power Quality Analyzer was connected which revealed extremely high levels of voltage distortion during drilling operations. Deep notches, visible in the voltage waveform, were found to be the result of SCR's in the mud pump DC Drives. Total harmonic voltage distortion (VTHD) reached 25%. A series connected passive filter was installed ahead of the centrifuge equipment to reduce the voltage notching and lower voltage distortion. The filter reduced notch depth by more than half and lowered overall voltage distortion at the centrifuge panel to <;9% during the most severe drilling operations. With line side voltage distortion levels remaining in the 20% range, the filter proved to be extremely effective in eliminating all centrifuge operational and premature failure issues.
机译:通常在陆地和海上钻机上使用的交流和直流驱动器会产生极高水平的谐波失真。由于电压畸变通常超过20%,与钻井作业相关的设备可能会遇到不稳定的操作和设备损坏。反复损坏一台或多台交流变频器很常见。阿尔伯塔省北部的一个陆地钻机每周都有离心机故障。一次访问该站点时,发现离心机中的驱动器跳闸,导致离心机堵塞。清理离心机并恢复驱动器后,在恢复钻孔操作后不久,驱动器再次跳闸。连接了电能质量分析仪,该质量分析仪在钻孔操作期间显示出极高的电压失真程度。在电压波形中可见的深凹口被发现是泥浆泵直流驱动器中SCR的结果。总谐波电压失真(VTHD)达到25%。在离心设备之前安装了一个串联的无源滤波器,以减少电压陷波并降低电压失真。在最严苛的钻孔操作中,该过滤器将陷波深度减小了一半以上,并将离心机面板上的总电压失真降低至<; 9%。由于线路侧的电压畸变水平保持在20%的范围内,因此该过滤器在消除所有离心机运行和过早失效问题方面被证明非常有效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号