首页> 外文会议>2014 29th International Conference on Microelectronics Proceedings >Comparison of resistive and capacitive strain gauge sensors printed on polyimide substrate using ink-jet printing technology
【24h】

Comparison of resistive and capacitive strain gauge sensors printed on polyimide substrate using ink-jet printing technology

机译:使用喷墨印刷技术在聚酰亚胺基板上印刷的电阻式和电容式应变仪传感器的比较

获取原文
获取原文并翻译 | 示例

摘要

In this paper we compared a resistive and capacitive strain gauge in terms of sensitivity and material cost, both printed with deposition material printer using silver nanoparticle ink on a flexible polyimide substrate. The resistive change due to strain was measured with a full Wheatstone bridge and a signal conditioning circuit, while the capacitance change was measured with the HP4194A impedance analyzer. Measured and derived strain gauge factor for resistive sensor was 1.10, and 0.91 for the capacitive sensor.
机译:在本文中,我们在灵敏度和材料成本方面比较了电阻应变式和电容应变式压力计,二者均使用沉积材料打印机在柔性聚酰亚胺基板上使用银纳米颗粒墨水进行打印。由于应变引起的电阻变化是通过完整的惠斯通电桥和信号调理电路测量的,而电容变化是通过HP4194A阻抗分析仪测量的。电阻传感器的测得和导出的应变仪系数为1.10,而电容传感器为0.91。