首页> 外文会议>2014 17th IEEE Mediterranean Electrotechnical Conference >Fuzzy logic based switching state selection for virtual flux DPC of shunt active filter
【24h】

Fuzzy logic based switching state selection for virtual flux DPC of shunt active filter

机译:并联有源滤波器虚拟磁链DPC的基于模糊逻辑的开关状态选择

获取原文
获取原文并翻译 | 示例

摘要

Active filters are effective for eliminating harmonic currents and compensating reactive power in the presence of non-linear loads and unbalanced sources. In this paper, a new strategy for control of shunt active filter is proposed. Fuzzy logic based switching state selection Direct Power Control (DPC) is employed for this control scheme. In addition, the AC line voltage sensors with a virtual flux (VF) estimator are replaced. To retrieve the phase and the frequency information, we have integrated a phase locked loop (PLL) control method. The advantages of this strategy are the simple algorithm, good dynamic response and resistance to the majority of the line voltage disturbances. Indeed, the operation of a proposed control strategy is implemented and verified in Matlab/Simulink's simulation environment. The results show that the control algorithm of the active filter is effective for eliminating harmonic currents and improving reactive power injected from nonlinear loads, which allowed us to confirm the robustness of the proposed strategy.
机译:在存在非线性负载和不平衡电源的情况下,有源滤波器可有效消除谐波电流并补偿无功功率。本文提出了一种控制并联有源滤波器的新策略。基于模糊逻辑的开关状态选择直接功率控制(DPC)用于此控制方案。此外,替换了具有虚拟磁通(VF)估算器的交流线路电压传感器。为了检索相位和频率信息,我们集成了锁相环(PLL)控制方法。该策略的优点是算法简单,动态响应好以及可抵抗大多数线路电压干扰。实际上,在Matlab / Simulink的仿真环境中实现并验证了所提出的控制策略的操作。结果表明,有源滤波器的控制算法对于消除谐波电流和改善非线性负载注入的无功功率是有效的,这使我们能够确定所提出策略的鲁棒性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号