With macrographic examination,SEM observation and fracture quantitative analysis technology,the fracture fractography of a spray tube with both the mechanical stress and the thermal stress in a boiler desuperheater of a power plant was interpreted,and the failure mode and the cause were researched.Results showed that rupture of the spray tube was due to the fatigue,and further,the thermal-mechanical fatigue.The alternating bending stress and thermal stress were main factors of the fracture failure.The shallow surface thermal fatigue cracks in tube inner wall were induced by thermal stress.When the thermal-mechanical fatigue crack grew up steadily to the shallow surface cracks zone,fast growth occurred and the local fast fracture zone generated which had different fractographies with final fast fracture zone of the normal fatigue fracture.
机译:通过宏观检验,SEM观察和断裂定量分析技术,解释了电厂锅炉减温器中同时受机械应力和热应力影响的喷管的断裂形貌,并研究了其失效模式和原因。结果表明,喷管的破裂是由于疲劳引起的,其次是热机械疲劳。弯曲应力和热应力的交变是造成断裂破坏的主要因素。当热机械疲劳裂纹稳定增长至浅表面裂纹区域时,发生了快速增长,并产生了局部快速断裂区域,其断裂形态与普通疲劳断裂的最终快速断裂区域不同。