首页> 外文会议>2013 International conference on materials for renewable energy amp; environment >The Impact of R50 on -100℃ three-stage Autocascade Refrigeration System
【24h】

The Impact of R50 on -100℃ three-stage Autocascade Refrigeration System

机译:R50对-100℃三级自动串级制冷系统的影响

获取原文
获取原文并翻译 | 示例

摘要

In this paper,a -100℃ three-stage auto-cascade refrigeration system is proposed and the experimental device is established.In order to determine the impact of R50 on the refrigeration cycle,the experiments are made by using mixed-refrigerants with R134a/R23/R14 and R134a/R23/R14/R50 containing the same quantity of R134a,R23 and R14 respectively in the same device.By analyzing and comparing the different effects of the two experiments,it is found that when R50 is added into the mixedrefrigerants,the evaporation temperature and the temperature after condensation at the second-stage and the third-stage partial condensers are lower,but the high pressure is increased.The higher the hige pressure is,the more power consumption is needed and more time is required to achieve the designed temperature.So it is harmful to the cycle performance of the three-stage autocascade refrigeration system when R50 is added into the mixed-refrigerants.
机译:本文提出了一种-100℃的三级自动级联制冷系统,并建立了实验装置。为确定R50对制冷循环的影响,采用了R134a / R23 / R14和R134a / R23 / R14 / R50在同一设备中分别包含相同数量的R134a,R23和R14。通过分析和比较两个实验的不同效果,发现将R50添加到混合制冷剂中,蒸发温度和第二级和第三级部分冷凝器冷凝后的温度较低,但高压升高。高压压力越高,所需的能耗就越多,需要的时间也就越多。将R50添加到混合制冷剂中会损害三级自动级联制冷系统的循环性能。