首页> 外文会议>2013 International Conference on Information Communication and Embedded Systems >Design of low-cost continuous temperature and water spillage monitoring system
【24h】

Design of low-cost continuous temperature and water spillage monitoring system

机译:低成本连续温度和水泄漏监控系统的设计

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Large number of accidents, related to the equipment safety, occurs in various hospitals across the globe due to negligence of few health care-givers. The negligence may result in the generation of sparks due to faulty conditions which may quickly spread and result in major casualties. In most of these cases, an accident could be prevented if the fire may be detected in its early stage. In general, it is very difficult to monitor all the areas of the hospital over a long period of time. Hence, this study was designed to develop a low-cost device for continuous monitoring of temperature and water spill in the medical equipments. LM35 temperature sensor was used for temperature monitoring whereas the water-spill detection unit was developed using a 555-timing device. An early detection of the water spill and/or rise in the environmental temperature within the equipment may help avoiding the outburst of fire on a large scale. The device is capable of continuously monitoring the equipment environment and gives an indication if there is any water spill or temperature anomaly.
机译:由于很少的医疗保健提供者的疏忽,全球各地的多家医院都发生了大量与设备安全有关的事故。过失可能会由于故障条件而导致火花的产生,故障条件可能会迅速蔓延并造成重大人员伤亡。在大多数情况下,如果可以在早期发现火灾,可以预防事故。通常,很难长时间监视医院的所有区域。因此,本研究旨在开发一种低成本的设备,用于连续监测医疗设备中的温度和洒水情况。 LM35温度传感器用于温度监控,而漏水检测单元是使用555定时装置开发的。尽早发现漏水和/或设备内环境温度的升高可能有助于避免大规模的起火。该设备能够连续监视设备环境,并指示是否有洒水或温度异常。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号