摘要

In this paper, it has been shown through measurements that violation of Radiated Emission (RE) threshold limit of MIL-STD-461F due to various kinds of cable connecting the Equipment Under Test (EUT) (inside the chamber) and test & monitoring equipment (outside the chamber) including the power source, occurs in a certain frequency range, the value of which depends on the length of the interfacing cables regardless of the unit being tested. It has further been demonstrated that when the power to EUT is supplied by placing batteries inside the chamber (as would be the case in actual system), the peculiar RE violations of MIL-STD-461F RE limits disappears, no matter which unit is being tested. This clearly indicates that the RE violations in this particular band are due to the cables connecting the power source with EUT. It is therefor proposed that if the batteries of adequate power are available, the system should be operated and tested for RE 102 compliance, by placing the batteries inside the chamber.
机译:在本文中,通过测量表明,由于连接被测设备(EUT)(箱内)和测试与监测设备的各种电缆,违反了MIL-STD-461F的辐射阈值限制包括电源在内的腔体(腔室外)出现在某个频率范围内,其频率值取决于接口电缆的长度,而与所测试的设备无关。进一步证明,当通过将电池放置在腔室内来为被测设备供电时(在实际系统中就是这种情况),无论是哪个单元,都违反了MIL-STD-461F RE限制的特殊RE规定消失了。经过测试。这清楚地表明,在此特定频段中违反RE的原因是由于电缆将电源与EUT连接在一起。因此建议,如果有足够功率的电池可用,则应通过将电池放入腔室内来操作和测试系统是否符合RE 102要求。