首页> 外文会议>2013 IEEE 5th International Symposium on Microwave, Antenna, Propagation and EMC Technologies for Wireless Communications >The research about the double ridge horn calibration in local EMC testing chambers Measurements and uncertainty evaluations
【24h】

The research about the double ridge horn calibration in local EMC testing chambers Measurements and uncertainty evaluations

机译:局部EMC测试室中双脊喇叭校准的研究测量和不确定度评估

获取原文
获取原文并翻译 | 示例

摘要

The accurate measurement of 1m antenna factor (AF) is a fundamental requirement for reliable EMC testing in RE102 followed by MIL-STD-461F. The double ridge horn (one of receiving antennas required by standard) with frequency 200MHz–1GHz is hard to transfer to calibration site for measuring because of its big dimension with 69.0cm by 94.5cm opening. In order to solve the problem and reduce the risk associated with transportation as well, a suitable indirect calibration method using a transfer antenna is described in the paper. At the frequency range from 200MHz to 1GHz, several experiments have been done and the results agree well with the calibration ones with the maximum discrepancy being 2.0 dB. A detailed experimental analysis is offered for estimating all the relevant uncertainty contributions and the expanded uncertainty is 1.7dB.
机译:1m天线系数(AF)的准确测量是RE102和MIL-STD-461F之后可靠的EMC测试的基本要求。频率为200MHz–1GHz的双脊形号角(标准要求的接收天线之一)很难转移到校准地点进行测量,因为它的大尺寸为69.0cm x 94.5cm。为了解决该问题并降低与运输相关的风险,在本文中描述了一种合适的使用转移天线的间接校准方法。在200MHz至1GHz的频率范围内,已进行了几次实验,结果与校准的结果吻合得很好,最大差异为2.0 dB。提供了详细的实验分析,以估计所有相关的不确定性贡献,扩展后的不确定性为1.7dB。