首页> 外文会议>2012 Compressor/Refrigeration amp; Air Conditioning/High Performance Buildings Conferences at Purdue >Development of Dual Compressor System using Compressor Combined with Expander for CO_2 Heat Pump Hot Water Heating System
【24h】

Development of Dual Compressor System using Compressor Combined with Expander for CO_2 Heat Pump Hot Water Heating System

机译:CO_2热泵热水供热系统的压缩机与膨胀机结合的双压缩机系统的研制。

获取原文
获取原文并翻译 | 示例

摘要

In order to prevent the global warming, reduction of CO_2 emissions, including the emissions from the domesticrnsector, on a global scale is required. In regions with cold climates, such as Europe, hot-water room heating,rnpowered by fossil fuel-burning boilers, composes the majority of energy consumption for heating. One of the CO_2rnheat pump hot-water heating equipment’s features is that it is capable of delivering high-temperature hot waterrnequivalent to that provided by the boilers. By focusing on this feature, we have aimed to construct high efficiencyrnCO_2 heat pump that can replace boilers to reduce CO_2 emissions through the reduction of primary energyrnconsumption. Thus, we constructed a compressor combined with an expander and the hybrid density proportionalrncontrol technology to develop high-efficiency heat pump system control, and enabled 15% improvement of anrnannual coefficient of performance (COP).
机译:为了防止全球变暖,需要在全球范围内减少CO_2的排放,包括来自国内部门的排放。在欧洲等气候寒冷的地区,由化石燃料燃烧锅炉提供动力的热水房采暖构成了供暖能耗的绝大部分。 CO_2热泵热水加热设备的特点之一是,它能够输送与锅炉提供的热水相当的高温热水。通过关注此功能,我们的目标是构建可替代锅炉的高效率rnCO_2热泵,以通过减少一次能源消耗来减少CO_2排放。因此,我们构建了一种与膨胀机和混合密度比例控制技术相结合的压缩机,以开发高效的热泵系统控制,并使年度性能系数(COP)提高了15%。

著录项

  • 来源
  • 会议地点 Purdue IN(US)
  • 作者单位

    Air-Conditioning and Cold Chain Development Center, Corporate Engineering Division, Appliances Company, Panasonic Corporation 2-3-1-2 Noji-higashi, Kusatsu City, Shiga, 525-8555, Japan Tel: +81-77-561-5658, Fax +81-77-563-1967, E-mail: shiotani.yu@jp.panasonic.com;

    Air-Conditioning and Cold Chain Development Center, Corporate Engineering Division, Appliances Company, Panasonic Corporation 2-3-1-2 Noji-higashi, Kusatsu City, Shiga, 525-8555, Japan;

    Energy Conversion System Development Center, Panasonic Corporation, 3-1-1 Yagumo-naka-machi, Moriguchi City, Osaka, 570-8501, Japan;

    Energy Conversion System Development Center, Panasonic Corporation, 3-1-1 Yagumo-naka-machi, Moriguchi City, Osaka, 570-8501, Japan;