首页> 外文会议>2012 16th International Symposium on Electromagnetic Launch Technology. >Analysis and measure the transient currents of rail-gun with loop probes
【24h】

Analysis and measure the transient currents of rail-gun with loop probes

机译:使用环形探头分析和测量轨道枪的瞬态电流

获取原文
获取原文并翻译 | 示例

摘要

Loop probes are used to measure the magnetic field nearby the rails of the rail-gun, and the total current can be measured by these loops too. Several loops are placed at one side of the rails along a straight line, and the transient current can be calculated with the measured magnetic field waveforms and distances between probes and currents for the long line current models. According to the error of fixing probes, and the position shift of the current for skin and adjacent effects and electromagnetic forces, distances between currents and probes are hard to get for each shot. If two probes are used together, it is easier to measure the single line current waveform. It is needless to get the distance between probes and currents beforehand. The current waveforms can be calculated only with the calibrated distance between two probes and field waveforms. For the rail-gun's rail currents, which have the same amplitudes but reverse directions, we can use three loop probes. The current waveforms can be easily got from the three magnetic field waveforms without knowing the shift positions of the rail currents. The commercial PEARSON current monitor model 1423 is used to calibrate and verify the results. The results are compared with each other for the single loop, two loops and three loops. The results show that it is proper to measure the transient currents with one loop or two loops, while it would be better when the three loops are used. The method is useful especially for the situations that the huge ROGOWSKI current probes are hard to fix with limited volume space.
机译:环形探头用于测量轨道炮轨道附近的磁场,总电流也可以通过这些环形回路进行测量。沿一条直线在轨道的一侧放置了多个回路,对于长线电流模型,可以使用测得的磁场波形,探头之间的距离和电流来计算瞬态电流。根据固定探针的误差以及皮肤和邻近效应以及电磁力的电流位置偏移,很难为每次发射获得电流和探针之间的距离。如果同时使用两个探头,则更容易测量单线电流波形。无需事先获取探头和电流之间的距离。只能使用两个探头之间的校准距离和场波形来计算电流波形。对于具有相同振幅但方向相反的轨道枪的轨道电流,我们可以使用三个环形探头。从三个磁场波形可以很容易地获得电流波形,而无需知道轨道电流的偏移位置。商用PEARSON电流监控器模型1423用于校准和验证结果。对于单个循环,两个循环和三个循环,将结果相互比较。结果表明,用一个回路或两个回路测量瞬态电流是适当的,而使用三个回路则更好。该方法特别适用于大型ROGOWSKI电流探头难以在有限体积空间内固定的情况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号