One of the greatest challenges toward developing guided wave structural health monitoring technology is the necessity to distinguish benign effects from those caused by damage. Variations in temperature, one of the most prominent benign effects, are known to stretch or scale ultrasonic signals in time. Several techniques have been proposed to compensate for the effects of temperature, but they tend to be computationally expensive, require locally convex conditions, or lack robustness to modeling error. In this paper, we present a new technique, based on the Mellin and scale transforms, which takes advantage of available fast algorithms for computing and compensating stretch-based operations. Using experimental data, we show our technique to be accurate, robust, and algorithmically faster than other existing techniques.
机译:开发导波结构健康监测技术的最大挑战之一是必须将良性影响与损坏造成的影响区分开。温度变化是最突出的良性影响之一,已知它会及时拉伸或缩放超声信号。已经提出了几种技术来补偿温度的影响,但是它们倾向于计算昂贵,需要局部凸条件或缺乏对建模误差的鲁棒性。在本文中,我们提出了一种基于Mellin和规模变换的新技术,该技术利用了可用的快速算法来计算和补偿基于拉伸的操作。使用实验数据,我们证明我们的技术比其他现有技术更准确,更可靠且算法更快。