首页> 外文会议>2011 7th Asia-Pacific International Conference on Lightning >Calculation of the 凢ield Intensification Factors. using Method of Moments for Lightning Protection
【24h】

Calculation of the 凢ield Intensification Factors. using Method of Moments for Lightning Protection

机译:增强强度因子的计算。使用瞬间法进行防雷

获取原文
获取原文并翻译 | 示例

摘要

This paper presents a fast and efficient way to calculate the ‘field intensification factors’ which can be used to assess the effectiveness of lightning rods for the protection of structures or to determine the likely lightning attachment points such as the corners and edges of structures and lightning rods. The approach allows for the three-dimensional calculation of the electric field around structures of complex shapes, represented by metallic plates and cylindrical conductor elements.Examples are given for various shapes and dimensions of typical structures, including lightning rods and composite structures. The effect on the field intensification factor of the geometry of the structure and of the rod dimensions and locations is investigated.
机译:本文提出了一种快速有效的方法来计算“场增强因子”,可用于评估避雷针在保护建筑物方面的有效性或确定可能的避雷针连接点,例如建筑物的拐角和边缘以及雷电棒。该方法可以对以金属板和圆柱导体为代表的复杂形状结构周围的电场进行三维计算,给出了各种形状和尺寸的典型结构示例,包括避雷针和复合结构。研究了结构的几何形状以及杆的尺寸和位置对场增强因子的影响。