首页> 外文会议>2010 9th International Conference on Environment and Electrical Engineering >A new concept in evaluating power system distortions under unbalanced and nonsinusoidal conditions
【24h】

A new concept in evaluating power system distortions under unbalanced and nonsinusoidal conditions

机译:在不平衡和非正弦条件下评估电力系统失真的新概念

获取原文
获取原文并翻译 | 示例

摘要

This paper presents a new index to evaluate a distorted signal under unbalanced and harmonic conditions. This criterion is called total harmonic and unbalanced distortion (THUD) which can be used to calculate the amount of harmonics and unbalance of voltage, current and power waveforms. Whereas conventional factors such as V/V+ and THD are fairly incomplete to express the total distortion of a signal in both harmonic and unbalanced environments, the use of alternative factors in such cases seems to be mandatory. It is demonstrated that the proposed voltage total harmonic and unbalanced distortion (VTHUD) along with voltage total harmonic distortion (VTHD) and voltage total unbalanced distortion (VTUD) are appropriate factors to achieve to this purpose. Furthermore, THUD is an extensive factor to compare two distorted environments from aspect of power quality issues.
机译:本文提出了一种新的指标来评估不平衡和谐波条件下的失真信号。此标准称为总谐波和不平衡失真(THUD),可用于计算谐波量以及电压,电流和功率波形的不平衡。尽管常规因素(例如V / V + 和THD)在表达谐波和不平衡环境中信号的总失真方面是相当不完善的,但在这种情况似乎是强制性的。结果表明,提出的电压总谐波和不平衡失真(VTHUD)以及电压总谐波失真(VTHD)和电压总不平衡失真(VTUD)是达到此目的的合适因素。此外,THUD是从电能质量问题的角度比较两个失真环境的重要因素。