EXPERIMENTAL INVESTIGATION ON SEISMIC BEHAVIOR OF HIGH PERFORMANCE CONCRETE SHEAR WALL WITH EDGE COLUMNS

机译:高性能边柱混凝土剪力墙抗震性能的试验研究。

获取原文

摘要

A new stirrup arrangement of independent closed reinforcement hoops nested with each other in six high performance concrete shear walls (HPCW) with edge columns was developed, and verified by the pseudo-static test. All specimens were proportioned according to the theory of performance-based design. The height-length ratios of specimens are 2, 1.5 and 1 respectively, and axial load ratios of 0.28 to 0.40 are used. The cubic compressive strength of concrete varies from approximately 89MPa to more than 99MPa for different specimens. The strength of stirrup is 737.5MPa. The lateral deformation, load-bearing capacity and energy dissipation capacity were critically examined. The effect of the quantities and scope of stirrup loops, axial load ratio, and the aspect ratio on load bearing capacity, deformability, the energy dissipation capacity of HPCW with edge columns were analyzed. The displacement ductility measured was 6.25~8.92, the coefficients of energy dissipation were 0.76~1.31.Results show that the new stirrup arrangement effectively improves the seismic behavior of the HPSW with edge columns.
机译:开发了一种新的独立的封闭式钢筋箍箍箍结构,该箍筋相互嵌套在带有边柱的六个高性能混凝土剪力墙(HPCW)中,并通过拟静力试验进行了验证。所有样本均根据基于性能的设计理论进行比例分配。试样的高长比分别为2、1.5和1,轴向载荷比为0.28至0.40。对于不同的试样,混凝土的立方抗压强度从大约89MPa到大于99MPa不等。箍筋的强度为737.5MPa。对其横向变形,承载力和能量耗散能力进行了严格的检查。分析了箍筋环的数量和范围,轴向载荷比和纵横比对带有边柱的高性能混凝土的承载能力,变形能力和能量耗散能力的影响。测得的位移延性为6.25〜8.92,能量耗散系数为0.76〜1.31。结果表明,新型箍筋布置有效地改善了边柱HPSW的抗震性能。