【24h】

DYNAMIC CHARACTERISTICS OF DESULFURIZATION TOWER UNDER DIFFERENT SEISMIC INPUT ANGLES USING SHAKING TABLE TEST

机译:振动台试验在不同输入角度下脱硫塔的动力特性

获取原文

摘要

The dynamic behavior of a desulfurization tower is tested using shaking table with a 1:15 scaled steel model to simulate the impacts caused by the earthquakes. The dynamic characteristics of the model have been analyzed. The responses of acceleration peak have been studied on the sine wave and earthquake wave in various angles. The results show that the influence of input angles of excitation wave can not be ignored. And the complexity of thin-wall desulfurization tower can affect the dynamic characteristics of the structure to a great extent. It can provide the experimental basis for the theoretical research of the large thin-wall heterotypic structure.
机译:使用带有1:15比例钢模型的振动台测试脱硫塔的动态行为,以模拟地震造成的影响。分析了模型的动态特性。研究了正弦波和地震波在不同角度下加速度峰值的响应。结果表明,激励波输入角的影响不容忽视。薄壁脱硫塔的复杂性会在很大程度上影响结构的动力特性。可为大型薄壁异型结构的理论研究提供实验依据。