首页> 外文会议>2004 International Refrigeration and Air Conditioning Conference at Purdue vol.1; 20040712-15; West Lafayette,IN(US) >MODIFIED WILSON-PLOT TECHNIQUE FOR HEAT EXCHANGER PERFORMANCE: STRATEGIES FOR MINIMIZING UNCERTAINTY IN DATA REDUCTION
【24h】

MODIFIED WILSON-PLOT TECHNIQUE FOR HEAT EXCHANGER PERFORMANCE: STRATEGIES FOR MINIMIZING UNCERTAINTY IN DATA REDUCTION

机译:换热性能的改进威尔森绘图技术:减少数据减少不确定性的策略

获取原文
获取原文并翻译 | 示例

摘要

The so-called 'modified Wilson-Plot' technique is commonly accepted as the preferred method for interpreting air-side heat transfer performance data for liquid- and refrigerant-to-air heat exchangers. Indeed, there are good reasons to believe Wilson-Plot techniques are superior to alternative data interpretation schemes. Unfortunately, Wilson-Plot methods are conceptually and computationally more complex than the other methods and it is not possible to simply extend the single-sample uncertainty analysis of Kline and McClintock to the modified Wilson-Plot technique. A rational approach to uncertainty analysis for the modified Wilson-Plot is not available in the literature, but if this method—accepted as superior to others—is to be widely adopted, a well-defined approach to uncertainty analysis is needed. The purpose of this paper is to provide an uncertainty analysis appropriate for the modified Wilson-Plot technique.
机译:作为解释液体和制冷剂-空气热交换器的空气侧传热性能数据的首选方法,通常接受所谓的“改进的Wilson-Plot”技术。确实,有充分的理由相信Wilson-Plot技术优于替代数据解释方案。不幸的是,Wilson-Plot方法在概念和计算上比其他方法更为复杂,不可能将Kline和McClintock的单样本不确定性分析简单地扩展到改进的Wilson-Plot技术。修改后的Wilson-Plot的不确定性分析的合理方法尚无文献报道,但是,如果要广泛采用这种方法(公认优于其他方法),则需要一种定义明确的不确定性分析方法。本文的目的是提供适用于改进的Wilson-Plot技术的不确定性分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号