A method of test is defined and instantiated for integral-collector-storage solar systems with a load-side heat exchanger immersed in the storage. A "system test/model calibration" approach is used. The test protocol consists of short-term tests and an extended validation test. Short-term tests include warmup tests, a decay test, and heat exchanger tests. The model parameters to be determined are the normal incidence transmission-absorption product, an additive correction to the total heat loss, and heat exchanger parameters correlating the ratio of modeled to measured heat exchanger fluxes. The calibrated system model resulting from the short-term tests is then validated against typical operation data. The calibrated model presented here under-predicts delivered energy over a 5-day period of normal operation by 11%, perhaps because of the present lack of modeling for the tank stratification induced during charging by solar radiation.
机译:定义并实例化了一种测试方法,该方法用于将集电器侧热交换器浸入存储中的整体集热器存储太阳能系统。使用“系统测试/模型校准”方法。该测试协议包括短期测试和扩展的验证测试。短期测试包括预热测试,衰减测试和热交换器测试。要确定的模型参数是法向入射透射吸收乘积,总热量损失的累加校正,以及将模型流量与测量的热交换器流量之比相关的热交换器参数。然后根据典型的操作数据验证由短期测试产生的校准系统模型。此处提供的经过校准的模型低估了正常运行5天期间提供的能量11%的情况,这可能是由于目前缺乏对太阳辐射充电过程中引起的储罐分层的建模的原因。