【24h】

FORCED CONVECTION HEAT TRANSFER IN THE COMBINED ENTRY REGION OF NON-CIRCULAR DUCTS

机译:非圆管组合进气区的强制对流传热

获取原文
获取原文并翻译 | 示例

摘要

A new model for predicting Nusselt numbers in the combined entrance region of non-circular ducts and channels is developed. This model predicts both local and average Nusselt numbers and is valid for both isothermal and isoflux boundary conditions. The model is developed using the asymptotic results for flow past flat plates, thermally developing flows in non-circular ducts, and fully developed flow in non-circular ducts. Through the use of a novel characteristic length, the square root of cross-sectional area, the effect of duct shape on Nusselt number is minimized. Comparisons are made with several existing models for the circular tube and parallel plate channel and with numerical data for several non-circular ducts. Agreement between the proposed model and numerical data is within +-15 percent or better for most duct shapes.
机译:开发了一种预测非圆形管道和通道组合入口区域中的Nusselt数的新模型。该模型可预测局部Nusselt数和平均Nusselt数,并且对于等温和等通量边界条件均有效。该模型是使用通过平板的流动的渐近结果,非圆形管道中的热流和非圆形管道中的完全流的渐近结果而开发的。通过使用新颖的特征长度(截面积的平方根),将导管形状对Nusselt数的影响降至最低。比较了几种现有的圆形管和平行板通道模型,以及几种非圆形管道的数值数据。对于大多数风管形状,建议的模型与数值数据之间的一致性在+ -15%或更好的范围内。