BRANZ, as an independent testing laboratory to the building industry, has developed an EmbeddedrnFastener Test for the measurement of metallic corrosion rates in treated timbers. In this work, thernperformance of this embedded fastener methodology has been compared with the American WoodrnPreservers' Association (AWPA) standard E12-94 test, which uses the corrosion analysis ofrnmetallic coupons 'sandwiched' between two timber blocks. The testing focused on the CCArnalternatives ACQ and CuAz timber preservative treatments. AWPA E12-94 mild steel corrosionrnrates in the ACQ treated timber have been shown to increase by a factor of up to five at the H3.2rnhazard level relative to the equivalent CCA treated timber. 316 stainless steel performed very wellrnfor all of the preservative treatments examined. The relative magnitude of corrosion rates measuredrnusing the Embedded Fastener Test contrasted significantly with those determined using the AWPArnstandard methodology. Using commercially available mild steel and hot-dipped galvanised nails,rnthe ACQ treated timber produced corrosion rates ranging from one and a half to two times that ofrnthe equivalent H3.2 CCA treated samples. It is concluded that the AWPA standard test increasesrnthe differentiation of mild steel corrosion rate between timber treatment types, but the relativernmagnitude of acceleration cannot be directly compared to that experienced by fasteners embeddedrnin the same timbers.
机译:BRANZ作为建筑行业的独立测试实验室,已经开发了EmbeddedFastener测试,用于测量经过处理的木材中的金属腐蚀速率。在这项工作中,该嵌入式紧固件方法的性能已与美国伍德恩保护者协会(AWPA)标准E12-94测试进行了比较,该测试使用了“夹在”两个木块之间的金属试样的腐蚀分析。测试重点在于CCArnalternatives ACQ和CuAz木材防腐处理。已证明,在AC3处理过的木材中,AWPA E12-94低碳钢的腐蚀速率在H3.2危害等级下相对于CCA处理过的等效木材提高了五倍。 316不锈钢在所有防腐处理中均表现出色。使用嵌入式紧固件测试测得的相对腐蚀速率与使用AWPArnstandard方法测得的相对速率显着不同。使用市售的低碳钢和热浸镀锌钉,经ACQ处理的木材产生的腐蚀速率是同等H3.2 CCA处理的样品的腐蚀速率的一半至两倍。结论是,AWPA标准测试增加了不同木材处理类型之间的低碳钢腐蚀速率的区别,但是加速度的相对大小不能直接与嵌入相同木材中的紧固件所经历的进行比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号