首页> 外文会议>16th annual North American waste to energy conference : Contract negotiations and plant expansions ; Conversion technologies ; WTERT: Focus on new technologyies ... >The Effects of Varied Hydrogen Chloride Gas Concentrations on Corrosion Rates of Commercial Tube Alloys under Simulated Environment of WTE Facilities
【24h】

The Effects of Varied Hydrogen Chloride Gas Concentrations on Corrosion Rates of Commercial Tube Alloys under Simulated Environment of WTE Facilities

机译:模拟WTE设备环境下不同浓度的氯化氢气体浓度对商用管合金腐蚀速率的影响

获取原文
获取原文并翻译 | 示例

摘要

In order to clarify the effects of HCl concentrations on corrosion rates of commercial tubing in Waste-to-Energy (WTE) boilers, a corrosion test was made by altering the HCl concentration from 0 to 1000ppm, together with simulated flue gas composition. Three commercial tubing SA178A, SA213 T11 and NSSER-4 samples were investigated under a well controlled thermal gradient where the gas temperature was at 700℃ and metal temperatures ranged from 480 to 580℃. The duration of each test was 100 hours. The post-test analyses included observations of surface morphology and elementary composition analysis of corrosion products by scanning electron microscope (SEM) and energy dispersive spectroscopy (EDS). The corrosion rates were acquired by measuring the mass loss of samples after the test.rnThe results showed that the addition of HCl to the flue gas increased the corrosion rates of test samples, but the relation between the HCl concentration and corrosion rate was not linear. The HCl effects on corrosion rates were more prominent when its concentration changed from 0 to 500ppm. In addition, the HCl effects were promoted by the increase of metal temperature inrnparticular when metal temperature was over 560℃.
机译:为了阐明HCl浓度对废料发电(WTE)锅炉中商业管道腐蚀速率的影响,通过将HCl浓度从0更改为1000ppm以及模拟烟气成分进行了腐蚀测试。在良好控制的热梯度下研究了三个商业管道SA178A,SA213 T11和NSSER-4样品,其中气体温度为700℃,金属温度为480至580℃。每次测试的持续时间为100小时。测试后分析包括通过扫描电子显微镜(SEM)和能量色散光谱(EDS)观察腐蚀产物的表面形态和元素组成。通过测量试验后样品的质量损失来获得腐蚀速率。结果表明,向烟道气中添加HCl可以提高样品的腐蚀速率,但是HCl浓度与腐蚀速率之间的关系不是线性的。当浓度从0变为500ppm时,HCl对腐蚀速率的影响更加明显。另外,当金属温度超过560℃时,特别是金属温度升高,促进了HCl的作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号