THERMAL ANALYSIS OF A SPENT FUEL TRANSPORTATION CASK

机译:燃油运输罐的热分析

获取原文
获取原文并翻译 | 示例

摘要

Spent fuel transportation casks are required to meet among others, the regulatory thermal test conditions in order to demonstrate their ability to withstand specified accidental fire conditions during transport. This paper describes the transient thermal analysis performed with the above intention for a transportation cask that has not undergone drop test and is not damaged. The original dimensions are used for computations. The analysis was carried out using a heat conduction code employing the Finite Element Method (FEM). At the outset, a benchmark exercise was carried out with the present code to ascertain its capability to carry out calculations involving phase change. The benchmarking was done against the solution given by commercial CFD code STAR CD. After assessing the suitability of the FEM code, it was employed for thermal analysis of the transportation cask. The computation covers normal transport condition, half an hour fire test at 800℃ and also the post fire cool down period. The objective of the analysis was to determine the maximum outer surface temperature for normal transport conditions and to assess the extent of melting of lead during fire and post fire period.
机译:用过的燃料运输桶必须满足规定的热测试条件,以证明其在运输过程中能够承受特定的意外着火条件。本文介绍了针对未经过跌落测试且未损坏的运输桶,出于上述目的进行的瞬态热分析。原始尺寸用于计算。使用热传导法,采用有限元法(FEM)进行分析。首先,对本规范进行了基准测试,以确定其执行涉及相变的计算的能力。基准测试是针对商业CFD代码STAR CD给出的解决方案进行的。在评估了FEM代码的适用性之后,将其用于运输桶的热分析。计算包括正常运输条件,在800℃下进行的半小时耐火试验以及后冷却时间。分析的目的是确定正常运输条件下的最高外表面温度,并评估着火期间和火灾后铅的熔化程度。