首页> 外文会议>The 13th Pacific Basin Nuclear Conference: Abstracts Oct 21-25, 2002 Shenzhen, China >Qualification Tests of Electric Valve Actuator with Category K1, Class 1E for Nuclear Power Plants
【24h】

Qualification Tests of Electric Valve Actuator with Category K1, Class 1E for Nuclear Power Plants

机译:核电厂1E级K1类电动阀执行器的资格测试

获取原文
获取原文并翻译 | 示例

摘要

The electric valve actuator has been researched and developed in order to meet thernlocalization of valves for nuclear power plant. According to the requirements ofrnIEEE-382-1996, it is necessary to provide assurance that safety system equipments in nuclearrnpower plants can meet their performance requirements under defined conditions, includingrnpostulated design basis events (DBE). Accelerated thermal aging test, mechanical wear agingrntest, normal and DBE radiation exposure test, vibration aging test and seismic simulation test,rnand DBE environment (LOCA) test should be performed in the development of electric valvernactuator with Category K1, Class 1E for nuclear power plant. This paper mainly summarizesrnthese qualification tests that provide the basis for the electric actuator to operate normallyrninside containment of PWR.
机译:为了满足核电站阀门的国产化,已经研究开发了电动阀门执行器。根据IEEE-382-1996的要求,有必要确保核电厂的安全系统设备在定义的条件下能够满足其性能要求,包括假定的设计基准事件(DBE)。在核电站用K1类1E级电动阀门执行机构的开发中,应进行加速的热老化测试,机械磨损老化测试,正常和DBE辐射暴露测试,振动老化测试和地震模拟测试,DBE环境(LOCA)测试。 。本文主要总结了这些合格测试,这些测试为电动执行器在压水堆安全壳内正常运行提供了依据。