This paper describes application of ATP-EMTP in the modelling and simulation of CT and differential protection IED for determination of appropriate settings. It describes a methodology to integrate the mathematical concepts of IEC 60044-6 with simulation capability of ATP-EMTP to quantitatively determine the problems posed by CT saturation for a given case; and arrive at the settings which offer highest degree of sensitivity without sacrificing stability.
机译:本文介绍了ATP-EMTP在CT和差动保护IED的建模和仿真中的应用,以确定合适的设置。它描述了一种方法,该方法将IEC 60044-6的数学概念与ATP-EMTP的仿真功能集成在一起,以定量确定给定情况下CT饱和带来的问题;并获得在不牺牲稳定性的前提下提供最高灵敏度的设置。