首页> 外文会议>12th IET International Conference on Developments in Power System Protection >A novel energy ratio direction relay based on equivalent traveling wave process
【24h】

A novel energy ratio direction relay based on equivalent traveling wave process

机译:基于等效行波过程的新型能量比方向继电器

获取原文
获取原文并翻译 | 示例

摘要

Effective analysis method is required to analyze the entire traveling wave (TW) process, which includes the initial and succeeding TWs. As TW directional protection only uses the initial TWs to avoid potential confusion that may be caused by the aliasing of TWs, a long-term reliable criterion is difficult to offer. Thus, this paper proposes an analysis method for the whole TW process based on an equivalent TW process and a novel directional protection approach. Based on this equivalent TW process, the protection can overcome the limit of presenting long-term criterion, the problem of detecting a fault close to the relay location, and the insufficient sensitivity under the fault with an inception angle near zero that troubles the conventional TW directional protection. Extensive simulation of EMTP/ATP verified the performance of this protection.
机译:需要一种有效的分析方法来分析整个行波(TW)过程,包括初始和后续的TWs。由于TW定向保护仅使用初始TW来避免可能由于TW的混叠而引起的潜在混淆,因此很难提供长期可靠的判据。因此,本文基于等效TW过程和新颖的方向保护方法,提出了整个TW过程的分析方法。基于这种等效的TW过程,该保护可以克服提出长期标准的局限性,在靠近继电器位置处检测故障的问题以及在初始角度接近零的故障下灵敏度不足,这给常规TW带来了麻烦。方向保护。 EMTP / ATP的广泛仿真证明了这种保护的性能。