The increasing utilization of the mixed line requires more reliable technique to identify the fault section to overcome all the disadvantages of the existing schemes. Distance relay technique is not accurate and limited to one configuration of mixed line while the differential relay is more expensive since it requires more measurement hardware in the junction points and related communication channels along the whole length of the line. Based on the modern communication technology and digital signal processing technology development such as global positioning system (GPS) and high sampling frequency introduction in the signal processing domains, an accurate scheme with reasonable price is needed to identify fault section and configure the auto reclosing scheme to meet the increased demand on the mixed line.
机译:混合线路利用率的提高需要更可靠的技术来确定故障区域,以克服现有方案的所有缺点。距离继电器技术不准确,并且仅限于混合线路的一种配置,而差分继电器则更昂贵,因为它在沿线路的整个长度的连接点和相关的通信通道中需要更多的测量硬件。基于现代通信技术和数字信号处理技术的发展,例如全球定位系统(GPS)和信号处理领域中的高采样频率引入,需要一种价格合理的精确方案来识别故障区域并配置自动重合闸方案以满足混合线路上不断增长的需求。