Improvement of Main Insulation Structure for 110kV Electric Power Transformer based on Electric Field Analysis

机译:基于电场分析的110kV电力变压器主绝缘结构改进

获取原文

摘要

Main insulation structure for 110kV electric power transformer is improved based on electric field Analysis. FEM is introduced to calculate the electric filed of primary and improved main insulation structure. The electric field distribution is shown, and maximum electric field intensity and its position are given. The advantage for improved main insulation structure is obtained from the cost comparison between primary and improved main insulation structure of transformer. The validity of main insulation structure has been proved by insulation test to electric power transformer.