首页> 外文会议>2019 10th International Conference on Power Electronics and ECCE Asia >Fault Analysis and Fault-Tolerant Method of Dual Active Bridge Converter under Triple Phase Shift Control
【24h】

Fault Analysis and Fault-Tolerant Method of Dual Active Bridge Converter under Triple Phase Shift Control

机译:双相桥控制下双有源桥变换器的故障分析及容错方法

获取原文
获取原文并翻译 | 示例

摘要

The open circuit fault on switches serious threat safe operation of DAB converter. In this paper, the fault phenomena of different switches during various operation condition under triple phase shift control is presented. Based on those analysis, the advanced fault diagnose which uses midpoint voltage as diagnosis criteria. It can ensure fast detect and accurate locate failure switch. After the failure switch is located, fault-tolerant is presented to maintain power transmission ability of DAB converter and ensure safe operation. Experimental result of proposed open circuit fault performance, fault diagnose method and fault-tolerant method is validated with experimental result.
机译:开关的开路故障严重威胁了DAB转换器的安全运行。提出了在三相移控制下,各种开关在各种工况下的故障现象。基于这些分析,可以使用中点电压作为诊断标准进行高级故障诊断。它可以确保快速检测和准确定位故障开关。定位故障开关后,将提供容错功能,以维持DAB转换器的功率传输能力并确保安全操作。实验结果验证了所提出的开路故障性能,故障诊断方法和容错方法的实验结果。