A blackout usually starts with the failure of electrical power equipment, especially transmission lines. However, the fault probability of a transmission line is often assumed to have a specific value in the existing risk analysis, regardless of the complicated conditions and effectiveness. In this paper, we first decompose the transmission line risk sources into six components: line swaying, thunderstorms, exogenic force, equipment failure, human accident and wildfires. Secondly, the transmission line is compartmentalized into several monitor functioning areas according to geographical environment and statistic characteristics. Thirdly, a new framework and methodology of vulnerability analysis based on various data resources are presented. The Bayesian theorem is next used to analyze the vulnerabilities of transmission lines. Finally, simulations and experiments are employed to demonstrate the feasibility of the proposed method.
机译:停电通常始于电力设备,尤其是输电线路的故障。然而,在现有的风险分析中,无论条件和有效性如何复杂,通常都认为传输线的故障概率具有特定的值。在本文中,我们首先将输电线路风险源分解为六个部分:线路摇摆,雷暴,外力,设备故障,人身事故和野火。其次,根据地理环境和统计特征,将传输线划分为几个监视功能区域。第三,提出了基于各种数据资源的脆弱性分析的新框架和方法。接下来,使用贝叶斯定理分析传输线的脆弱性。最后,通过仿真和实验证明了该方法的可行性。