【24h】

Study of treatment of oil pollution from water with electro-Fenton technology

机译:电Fenton技术处理水质油污染的研究

获取原文

摘要

An advanced technology, double poles electro-Fenton system was used to treat oil pollution from water. Effects of electricity density, pH value and initial oil concentration were studied to test and to validate the kinetic model for the oxidation of oil pollution by the electro-Fenton process. The degradation of oil was a simulated second order reaction, and the degradation efficiency of oil was decreased with the increase of pH from 2.5 to 7.0, while increased with the increase of current density from 5 to 25 mA/cm2. The results showed that at experimental condition, the double poles electro-Fenton system had high removal efficiency for oil pollution from water.
机译:一种先进的技术,双极电芬顿系统用于处理水中的油污。研究了电密度,pH值和初始油浓度的影响,以测试和验证电芬顿法氧化油污染的动力学模型。油的降解是模拟的二级反应,油的降解效率随pH值从2.5增加到7.0降低,而随电流密度从5 mA / cm2增加而增加。结果表明,在实验条件下,双极电芬顿系统对水中的油污具有较高的去除效率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号